Micro controller directional over current relay study trainer MICRO CONTROLLER BASED DIRECTIONAL OVER CURRENT RELAY One no. of PIC-Micro controller used as processor to read fault-current, & Voltage phase angle & relay function.One no. LCD to indicate Current & Time Constants.Four no. of key used for Set Point adjustmentsOne no. of 5A CT used to sense fault currentOne no. of 230/9V PT used to sense voltageOne no. of ZCD for phase angle measurement.One no. of 12V auxiliary relay used for contractor operation.One no of LED to indicate the relay tripping operation SPECIFICATION:Current input: 0-5 Amp.Voltage input: 0-230VPhase diff.: 0-89 deg.of contact: One no. NC contact @ 220V, 5Amp ratingOne no. of NO contact @ 220V, 5Amp rating.Auxiliary supply: 230V AC, 50HzPower ON/OFF switch with indictor.CURRENT & VOLTAGE INJUCTION SOURCEOne no. of auto transformer 8A used for current adjustment.One no. of auto transformer 8A used for Voltage adjustment so as phase angle adjustment.Two no’s of loading & phase shifting transformer provided for current and phase Adjustment (230/16V, 4A)Current & Voltage output terminated in the banana-sockets.Specification: Current range: 0-5 Amp AC. (continuously variable) phase Diff 0-90 deg. (w.r.t. voltage)