V Instruments

Micro controller based three phase differential relay study trainer (merz -price protection scheme)

MICRO CONTROLLER BASED DIFFERENTIAL RELAY

  • One no. of PIC Micro controller used as processor to read all current, (PY, SY) & activation of relay function.
  • One number LCD to indicate Current & Time Constants.
  • Four no. of key used for Set Point Adjustments.
  • Six number of 5A CT used to sense primary and secondary current.
  • One no. of 24V TPTT auxiliary relay used for contractor operation.

SPECIFICATION:

  • Current input: 0-5Amp
  • Voltage input: 0-230V
  • Three number NO contact @ 220V, 5 Amp rating.
  • Auxiliary supply: 230V AC, 50Hz
  • Power ON/OFF switches with indicator.

 THREE PHASE TRANSFORMER SET-UP

  • One no. of 24/24V three phase transformer with primary and secondary side inter winding termination for fault creation.
  • Star-star connection.
  • One no. of 415V/48V three phase transformers provided for fault transformer input voltage.
  • Three phase lamp load provided
  • Types of fault L-L, L-N can be created used termination.
  • One no of rheostat provided for variation of short circuit resistance.